BSI BS 6399-2 Loading for Buildings - Part 2: Code of Practice for Wind Loads


Purchase Information
Use this form to request purchase information on BSI online subscriptions.
BSI Collections
First Name:

Last Name:

Email address:

Document BSI BS 6399-2 is offered by IHS as part of an online subscription. This subscription contains many documents on the same topic.

You may also purchase this document alone from the IHS Standards Store.


BSI BS 6399-2 Document Information:

Title
Loading for Buildings - Part 2: Code of Practice for Wind Loads

British Standards Institution

Publication Date:
Jul 15, 1997

Scope:

This Part of BS 6399 gives methods for determining the gust peak wind loads on buildings and components thereof that should be taken into account in design using equivalent static procedures.

Two alternative methods are given:

a) a standard method which uses a simplified procedure to obtain a standard effective wind speed which is used with standard pressure coefficients to determine the wind loads for orthogonal design cases.

NOTE 1 This procedure is virtually the same as in CP3:Chapter V:Part 2.

b) a directional method in which effective wind speeds and pressure coefficients are determined to derive the wind loads for each wind direction.

Other methods may be used in place of the two methods given in this standard, provided that they can be shown to be equivalent. Such methods include wind tunnel tests which should be taken as equivalent only if they meet the conditions defined in Annex A.

NOTE 2 Wind tunnel tests are recommended when the form of the building is not covered by the data in this standard, when the form of the building can be changed in response to the test results in order to give an optimized design, or when loading data are required in more detail than is given in this standard.

Specialist advice should be sought for building shapes and site locations that are not covered by this standard.

The methods given in this Part of BS 6399 do not apply to buildings which, by virtue of the structural properties, e.g. mass, stiffness, natural frequency or damping, are particularly susceptible to dynamic excitation. These should be assessed using established dynamic methods or wind tunnel tests.

NOTE 3 See references [1] to [4] for examples of established dynamic methods.

NOTE 4 If a building is susceptible to excitation by vortex shedding or other aeroelastic instability, the maximum dynamic response may occur at wind speeds lower than the maximum.

Keywords:

Buildings
Wind loading
Climatic loading
Loading
Structural design
Velocity
Pressure
Dynamic pressure
Design calculations
Equations
Walls
Roofs
Shape
Height
Angles (geometry)
Length
Error correction
Topography

About IHS
IHS (NYSE: IHS) is a leading global provider of critical technical information, decision-support tools and related services in a number of industries including aerospace and defense, automotive, construction, electronics, and energy. IHS serves customers ranging from large governments and multinational corporations to smaller companies and technical professionals in more than 100 countries. IHS been in business for more than 45 years and employ more than 2,300 people around the world.

 