IHS Inc., Home - http://www.ihs.com

ASTM F 2248 Standard Practice for Specifying an Equivalent 3-Second Duration Design Loading for Blast Resistant Glazing Fabricated with Laminated Glass


Purchase Information
Use this form to request purchase information on ORG online subscriptions.
ASTM Collections
First Name:

Last Name:

Email address:

Document ASTM F 2248 is offered by IHS as part of an online subscription. This subscription contains many documents on the same topic.

You may also purchase this document alone from the IHS Standards Store.


ASTM F 2248 Document Information:

Title
Standard Practice for Specifying an Equivalent 3-Second Duration Design Loading for Blast Resistant Glazing Fabricated with Laminated Glass

ASTM International

Publication Date:
Aug 10, 2003

Scope:

This practice sets forth a method to specify an equivalent 3-second design loading suitable to use with Practice E 1300 to select the thickness and type of blast resistant glazing fabricated with laminated glass to glaze a fenestration.

This practice applies to blast resistant glazing fabricated using laminated glass only, including single laminated glass and insulating glass fabricated with laminated glass.

This practice assumes that blast resistant glazing shall be adhered to its supporting frame using structural silicone sealant or adhesive glazing tape. The width of the structural silicone sealant bead shall be at least equal to but not larger than two times the thickness designation of the glass to which it adheres. The width of glazing tape shall be at least equal to two times but not more than four times the thickness designation of the glass to which it adheres.

This practice assumes the framing members shall restrict deflections of edges of blast resistant glazing they support to L/160 under the equivalent 3-second duration design loading as determined herein, where L denotes the length of the supported edge.

This practice assumes the framing system supporting the blast resistant glazing shall attach mechanically to the structural framing system with fasteners that will resist forces generated by a uniform load acting on the blast resistant glazing that has a magnitude at least 2.0 times the magnitude of the 3-second equivalent design load as determined herein.

The equivalent 3-second design load as determined herein shall not apply to the design of monolithic glazing, plastic glazing, or security film applied to existing glazing configurations in an attempt to achieve blast resistance.

The values stated in SI units are to be regarded as the standard. Values given in parentheses are for information only. For conversion of quantities in various systems of measurements to SI units refer to ANSI IEEE/SI 10.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords:

air blast pressure
blast resistant glazing
explosion
insulating glass
laminated glass
specified design load

About IHS
IHS (NYSE: IHS) is a leading global provider of critical technical information, decision-support tools and related services in a number of industries including aerospace and defense, automotive, construction, electronics, and energy. IHS serves customers ranging from large governments and multinational corporations to smaller companies and technical professionals in more than 100 countries. IHS been in business for more than 45 years and employ more than 2,300 people around the world.

 