IEC 60601-2-1 Document Information:
Title
Medical Electrical Equipment - Part 2-1: Particular Requirements for the Safety of Electron Accelerators in the Range 1 MeV to 50 MeV
Appareils Electromedicaux - Partie 2-1: Regles Particulieres De Securite Pour Les Accelerateurs D´Electrons Dans La Gamme De 1 MeV A 50 MeV
International Electrotechnical Commission
Publication Date:
Jun 1, 1998
Scope:
Addition:
This Particular Standard, with the inclusion of TYPE TESTS and SITE TESTS, applies respectively to the manufacture and some installation1) aspects of ELECTRON ACCELERATORS2)
- intended for RADIOTHERAPY in human medical practice, including those in which the selection and DISPLAY of operating parameters can be controlled automatically by PROGRAMMABLE ELECTRONIC SUBSYSTEMS (PESS),
- that, under NORMAL CONDITIONS (NC) and in NORMAL USE, deliver a RADIATION BEAM of X-RADIATION and/or ELECTRON RADIATION having
• NOMINAL ENERGY in the range 1 MeV to 50 MeV,
• maximum ABSORBED DOSE3) RATES between 0,001 Gy x s-1 and 1 Gy x s-1 at 1 m from the RADIATION SOURCE,
• NORMAL TREATMENT DISTANCES (NTDS) between 0,5 m and 2 m from the RADIATION SOURCE,
and
- intended to be
• for NORMAL USE, operated under the authority of appropriately licensed or QUALIFIED PERSONS by OPERATORS having the required skills for a particular medical application, for particular specified clinical purposes, e.g. STATIONARY RADIOTHERAPY or MOVING BEAM RADIOTHERAPY,
• maintained in accordance with the recommendations given in the INSTRUCTIONS FOR USE,
• subject to regular quality assurance performance and calibration checks by a QUALIFIED PERSON,
• used within the environmental and electrical supply conditions SPECIFIED in the technical description.
1) In this Particular Standard, all references to installation refer to installation in the USER’S premises.
2) See ICRP 33 (128) - (134) and (144) - (156).
3) In this Particular Standard, all references to ABSORBED DOSE refer to ABSORBED DOSE in water.
About IHS
IHS (NYSE: IHS) is a leading global provider of critical technical information, decision-support tools and related services in a number of industries including aerospace and defense, automotive, construction, electronics, and energy. IHS serves customers ranging from large governments and multinational corporations to smaller companies and technical professionals in more than 100 countries. IHS been in business for more than 45 years and employ more than 2,300 people around the world.