ASTM D 4566 Standard Test Methods for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable
 |
| Purchase Information |
| Use this form to request purchase information on ORG online subscriptions. |
|
 |
Document ASTM D 4566 is offered by IHS as part of an online subscription. This subscription contains many documents on the same topic.
You may also purchase this document alone from the IHS Standards Store.
ASTM D 4566 Document Information:
Title
Standard Test Methods for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable
ASTM International
Publication Date:
Mar 1, 2005
Scope:
These test methods cover procedures for electrical testing of
thermoplastic insulations and jackets
used on telecommunications wire and cable and for the testing of
electrical characteristics of
completed products. To determine the procedure to be used on the
particular insulation or jacket
compound, or on the end product, reference should be made to the
specification for the product.
The test methods appear in the following sections of this standard:
The values stated in inch-pound units are to be regarded as the
standard. SI units are for
information only.
This standard does not purport to address all of the safety concerns,
if any, associated with its
use. It is the responsibility of the user of this standard to
establish appropriate safety and
health practices and determine the applicability of regulatory
limitations prior to use. Specific
hazard statements are given in Sections 6 and 37.
Keywords:
- aging
- attenuation
- attenuation to crosstalk ratio near-end
- attenuation to crosstalk ratio far-end
- capacitance deviation
- capacitance difference
- capacitance unbalance pair-to-pair
- capacitance unbalance pair-to-ground
- capacitance unbalance pair-to-support wire
- characteristic impedance
- coaxial capacitance
- conductor resistance
- conductor resistance unbalance
- continuity
- conversion loss
- crosses
- crosstalk loss - far end
- crosstalk loss - near end
- dc proof test
- equal level far-end crosstalk
- equal level unbalance attenuation far-end
- equal level unbalance attenuation near-end
- equal level longitudinal conversion transfer loss (EL LCTL)
- equal level transverse conversion transfer loss (EL TCTL)
- fault rate test
- humidity
- insulation defect
- insulation resistance
- jacket voltage breakdown
- longitudinal conversion loss (LCL)
- longitudinal conversion transfer loss (LCTL)
- mutual capacitance
- mutual conductance
- phase constant
- phase delay
- phase velocity
- shorts test
- spark test
- structural return loss
- transverse conversion loss (TCL)
- transverse conversion transfer loss (TCTL)
- unbalance attenuation far-end
- unbalance attenuation near-end
- voltage surge test
About IHS
IHS (NYSE: IHS) is a leading global provider of critical technical information, decision-support tools and related services in a number of industries including aerospace and defense, automotive, construction, electronics, and energy. IHS serves customers ranging from large governments and multinational corporations to smaller companies and technical professionals in more than 100 countries. IHS been in business for more than 45 years and employ more than 2,300 people around the world.