IHS Inc., Home - http://www.ihs.com

ASTM C 842 Standard Specification for Application of Interior Gypsum Plaster


Purchase Information
Use this form to request purchase information on ASTM online subscriptions.
ASTM Collections
First Name:

Last Name:

Email address:

Document ASTM C 842 is offered by IHS as part of an online subscription. This subscription contains many documents on the same topic.

You may also purchase this document alone from the IHS Standards Store.


ASTM C 842 Document Information:

Title
Standard Specification for Application of Interior Gypsum Plaster

ASTM International

Publication Date:
May 1, 2005

Scope:

(Footnote *)

This specification covers the minimum requirements for full-thickness (in accordance with Table 1) interior gypsum plastering on gypsum, metal, masonry, or monolithic concrete bases designed or prepared to receive gypsum plaster.

Gypsum plaster applied to the interior side of exterior walls of masonry or concrete shall be isolated from the exterior wall.

Gypsum plasters shall not be used in exterior locations or interior "wet" areas.

NOTE 1 - To secure desirable results, this specification should be coordinated with the provisions of Specification C 841. General information concerning full thickness gypsum plastering is contained in Annex A2, Annex A3, and Annex A4.

Details of construction for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing laboratories.

Details of construction to achieve required sound control shall be obtained from reports of tests conducted at recognized sound testing laboratories in accordance with the applicable sound tests of Test Methods E 90, C 423, or E 492.

The values stated in inch-pound units are to be regarded as the standard. The SI (metric) values given in parentheses are approximate and are provided for information purposes only.

The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

Footnote * - A Summary of Changes section appears at the end of this standard.

Keywords:

aggregate
basecoat
ceiling
finish coat
gypsum
lath
plaster
texture

About IHS
IHS (NYSE: IHS) is a leading global provider of critical technical information, decision-support tools and related services in a number of industries including aerospace and defense, automotive, construction, electronics, and energy. IHS serves customers ranging from large governments and multinational corporations to smaller companies and technical professionals in more than 100 countries. IHS been in business for more than 45 years and employ more than 2,300 people around the world.

 