IHS Inc., Home - http://www.ihs.com

ASTM E 905 Standard Test Method for Determining Thermal Performance of Tracking Concentrating Solar Collectors


Purchase Information
Use this form to request purchase information on ASTM online subscriptions.
ASTM Collections
First Name:

Last Name:

Email address:

Document ASTM E 905 is offered by IHS as part of an online subscription. This subscription contains many documents on the same topic.

You may also purchase this document alone from the IHS Standards Store.


ASTM E 905 Document Information:

Title
Standard Test Method for Determining Thermal Performance of Tracking Concentrating Solar Collectors

ASTM International

Publication Date:
Aug 28, 1987

Scope:

This test method covers the determination of thermal performance of tracking concentrating solar collectors that heat fluids for use in thermal systems.

This test method applies to one- or two-axis tracking reflecting concentrating collectors in which the fluid enters the collector through a single inlet and leaves the collector through a single outlet, and to those collectors where a single inlet and outlet can be effectively provided, such as into parallel inlets and outlets of multiple collector modules.

This test method is intended for those collectors whose design is such that the effects of diffuse irradiance on performance is negligible and whose performance can be characterized in terms of direct irradiance.

NOTE 1—For purposes of clarification, this method shall apply to collectors with a geometric concentration ratio of seven or greater.

The collector may be tested either as a thermal collection subsystem where the effects of tracking errors have been essentially removed from the thermal performance, or as a system with the manufacturer-supplied tracking mechanism.

The tests appear as follows:

This test method is not intended for and may not be applicable to phase-change or thermosyphon collectors, to any collector under operating conditions where phase-change occurs, to fixed mirror-tracking receiver collectors, or to central receivers.

This test method is for outdoor testing only, under clear sky, quasi-steady state conditions.

Selection and preparation of the collector (sampling method, preconditioning, mounting, alignment, etc.), calculation of efficiency, and manipulation of the data generated through use of this standard for rating purposes are beyond the scope of this test method, and are expected to be covered elsewhere.

This test method does not provide a means of determining the durability or the reliability of any collector or component.

The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords:

single-axis
thermal performance
tracking concentrating solar collectors
two-axis

About IHS
IHS (NYSE: IHS) is a leading global provider of critical technical information, decision-support tools and related services in a number of industries including aerospace and defense, automotive, construction, electronics, and energy. IHS serves customers ranging from large governments and multinational corporations to smaller companies and technical professionals in more than 100 countries. IHS been in business for more than 45 years and employ more than 2,300 people around the world.

 

Legal Statement | Site Map | Privacy Policy | Standards Store

Redirector