| Purchase Information |
| Use this form to request purchase information on ORG online subscriptions. |
|
 |
Document ASTM E 308 is offered by IHS as part of an online subscription. This subscription contains many documents on the same topic.
You may also purchase this document alone from the IHS Standards Store.
ASTM E 308 Document Information:
Title
Standard Practice for Computing the Colors of Objects by Using the CIE System
ASTM International
Publication Date:
Dec 1, 2006
Scope:
This practice provides the values and practical computation
procedures needed to obtain CIE tristimulus values from spectral
reflectance, transmittance, or radiance data for objectcolor
specimens.
Procedures and tables of standard values are given for computing
from spectral measurements the CIE tristimulus values X, Y, Z,
and chromaticity coordinates x, y for the CIE 1931 standard
observer and X 10, Y10, Z 10 and
x10. y10 for the CIE 1964 supplementary
standard observer.
Standard values are included for the spectral power of six CIE
standard illuminants and three CIE recommended fluorescent
illuminants.
Procedures are included for cases in which data are available
only in more limited wavelength ranges than those recommended, or
for a measurement interval wider than that recommended by the CIE.
This practice is applicable to spectral data obtained in accordance
with Practice E 1164 with 1-, 5-, 10-, or 20-nm measurement
interval.
Procedures are included for cases in which the spectral data
are, and those in which they are not, corrected for bandpass
dependence. For the uncorrected cases, it is assumed that the
spectral bandpass of the instrument used to obtain the data was
approximately equal to the measurement interval and was triangular
in shape. These choices are believed to correspond to the most
widely used industrial practice.
This practice includes procedures for conversion of results to
color spaces that are part of the CIE system, such as CIELAB and
CIELUV (3). Equations for calculating color differences in these
and other systems are given in Practice D 2244.
This standard does not purport to address all of the safety
concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and
health practices and determine the applicability of regulatory
limitations prior to use.
Keywords:
- CIELAB
- CIELUV
- CIE system
- color coordinates
- tristimulus integration
- tristimulus values
- tristimulus weighting factors
About IHS
IHS (NYSE: IHS) is a leading global provider of critical technical information, decision-support tools and related services in a number of industries including aerospace and defense, automotive, construction, electronics, and energy. IHS serves customers ranging from large governments and multinational corporations to smaller companies and technical professionals in more than 100 countries. IHS been in business for more than 45 years and employ more than 2,300 people around the world.