ASTM Int'l Approves Enteral Feeding Device Standard

July 3, 2006

 
Medical Device Documents
IHS medical device standards collections contain EU Directives and Harmonized Standards from the Official Journal of the European Union.
Complete this form for a free quote.
Medical Devices General
Active Implantable
Electromagnetic Compatibility
Low Voltage Equipment
In Vitro Diagnostic
ASTM Medical Devices
First Name:

Last Name:

Email Address:
A new standard, developed by ASTM International Committee F04 on Medical and Surgical Materials and Devices, establishes performance requirements for single-use, enteral feeding devices with retention balloons.

These devices are used by medical professionals to provide nutrition or administer medication to patients through a natural orifice (nasal, oral, transluminal) or through a surgically created stoma.

Enteral devices can be made in a variety of sizes out of silicone, urethane and various polymers. The new standard, ASTM F 2528 - Test Methods for Enteral Feeding Devices with a Retention Balloon - is under the jurisdiction of Subcommittee F04.35 on GI Applications.

Lisette Rice, president, Leading Medical Research (LMR), says that the origin for ASTM F 2528 was a market demand for a ballooned enteral feeding device that could withstand the harsh acidic conditions of the stomach. "If a feeding device cannot remain properly positioned in the established stoma via the retention balloon due to its failure, then often additional medical procedures have to be performed to extract the device and replace it with a new device," said Rice. "This results in the patient having to undergo additional procedures that may be preventable."

LMR developed a balloon that can withstand conditions inside the stomach for at least 90 days. During the R&D phase of the balloon development, LMR discovered that there was not an ASTM standard to cover the new device and began working with Subcommittee F04.35 to develop ASTM F 2528 to ensure the highest level of quality for end users of enteral feeding devices with retention balloons.

"Producers of enteral feeding devices that contain a retention balloon will be able to use F 2528 to provide them with quality assurance assessment and release criteria, as well as with a comparative testing baseline," said James Bardwell, manager, product development, Medi-Flex, Inc. Bardwell said the ASTM standard meets the goal of Subcommittee F04.35, which was to develop a "best practice" standardized set of enteral feeding devices that employ retention balloons. "In particular, a standardized method was needed to assess the performance of the balloons in a gastric fluid environment because of cost pressures and always changing reimbursement laws from state to state," said Bardwell.

Source: ASTM International.

ENGINEERING STANDARDS NEWS
November 5, 2009
ISO, ILAC, IAF Streamline Quality Mgmt. Requirements for Medical Labs
In a joint communiqué by the International Organization for Standardization (ISO), the International Laboratory Accreditation Cooperation (ILAC) ... more
October 30, 2009
ASTM D7558 Addresses Medical Glove Allergens
ASTM International issued a standard that allows rubber glove manufacturers to monitor the level of residual chemicals in their end products ... more
October 30, 2009
ANSI Begins Accreditation Under Toy Safety Certification Program
The American National Standards Institute (ANSI) accredited five certification bodies under the new Toy Industry Association (TIA) Toy Safety ... more
October 23, 2009
EU-China Standards Information Platform Launched
The European Committee for Standardization (CEN) announced the official launch of the new EU-China Standards Information Platform, a project ... more
October 16, 2009
DIN Announces Launch of Germany-China Standards Information Portal
The German Institute for Standardization (Deutsches Institut für Normung e.V., or DIN) announced the launch of the new Germany-China Standards ... more
Show All..